Galvanic Corrosion from Mixed Metal Pipework
I traced the potable water pipework and found dissimilar metals joined directly - most often copper connected to older galvanised steel with no dielectric break. Reference: AS/NZS 3500.1. In my experience the galvanic cell at the junction accelerates corrosion, narrowing the bore, discolouring the water, and eventually causing pinhole leaks. I see this most on partial re-pipes over an older galvanised system.
Causes
- Partial pipe replacement joining copper to legacy galvanised steel without a dielectric union
- Brass or stainless fittings installed directly onto galvanised risers
- Repairs completed without matching the existing pipework metallurgy
Symptoms to look for
- Rust-coloured or cloudy water on first draw, especially on hot
- Visible rust blooms, scaling or weeping at metal-to-metal junctions
- Reduced flow rate at outlets fed through the corroded section
Remedies
- Cut out the affected junctions and reinstate with a dielectric union or full like-for-like metal
- Plan a staged full re-pipe if the galvanised mains are near end of life
- Test water quality at outlets after rectification to confirm clarity
Get an inspector through this property.
Findings in this category skew high severity. If you are under contract, we can usually book inside the cooling-off window. Every inspection includes 12 months of free advice.