Skip to content
Defect type
Critical · 3–5/5

Non-Compliant Balustrade Height or Spacing

Compliance/real/pre–1970, 1970–2000/timber balustrade, metal balustrade

Balustrades on balconies, stairs, or elevated decks that do not meet BCA/NCC requirements for minimum height (1000mm), maximum opening spacing (125mm), or climbability provisions. A fall-prevention safety issue commonly found in pre-2000 homes.

Causes

  • Original construction predating current BCA height requirements
  • DIY modifications reducing effective balustrade height
  • Horizontal rail design allowing children to climb

Symptoms to look for

  • Balustrade height below 1000mm on balconies and decks
  • Openings between balusters exceeding 125mm
  • Horizontal rails or climbable elements within 150mm of floor

Remedies

  • Raise balustrade to minimum 1000mm height
  • Infill openings to comply with 125mm maximum gap
  • Replace horizontal rail design with vertical balusters or glass
Critical

Get an inspector through this property.

Findings in this category skew high severity. If you are under contract, we can usually book inside the cooling-off window. Every inspection includes 12 months of free advice.

Same category

More from Compliance

All entries →
9,237 inspections
242,618 defects found
30,388 defect types
Local franchise owners
Head office backing

Built to last. Inspected to be SURE.

One inspection, twelve months of advice, and the same person on the other end of the phone every time you call. That is the part you do not see on the brochure.

Same-day reports (subject to access and availability) 12 months free advice Your inspector reads every report
Start my quote
Or call 1300 787 327 business hours support

9,237 inspections · 242,618 defects found · Inspector-owned franchises