Internal Stair With Insufficient Headroom Clearance

Compliance/stairs/standard/pre–1970, 1970–2000, 2000–2015/timber stair, concrete stair

I measured the vertical clearance from the nosing line to the overhead soffit, bulkhead, rafter, or duct and recorded less than 2000mm at one or more points. Reference: NCC 3.9.1. I see this most often in attic conversions, under-stair storage cupboards reworked as habitable rooms, and split-level additions where an upper-floor bulkhead intrudes into the stair envelope. Head-strike injuries on such flights range from contusion to concussion, and in my experience the defect cannot be resolved without significant structural work.

Causes

  • Attic conversion with new stair cut into a roof-pitch-limited void
  • Upper-floor addition with bulkhead hanging into the existing stair envelope
  • HVAC duct, plumbing stack, or beam routed through the stairwell after construction
  • Original construction predates current clearance references
  • Under-stair ceiling dropped for insulation or services without checking the flight above

Symptoms to look for

  • I measured vertical clearance below 2000mm at one or more points along the nosing line
  • Occupants ducking or tilting head when ascending or descending
  • Visible scuff or strike marks on the soffit from head contact
  • Tall occupants reporting repeated head strikes
  • Beam, duct, or light fitting projecting into the stair envelope

Remedies

  • Relocate the offending duct, beam, or service outside the stair envelope
  • Rebuild the stairwell with a larger opening so clearance meets the NCC 3.9.1 reference
  • Reduce riser heights and extend the flight to shift the nosing line (major work)
  • Fit high-density padded strike protection as an interim mitigation
  • Document the defect in the inspection report as unlikely to be remediated without rebuild
Critical

Get an inspector through this property.

Findings in this category skew high severity. If you are under contract, we can usually book inside the cooling-off window. Every inspection includes 12 months of free advice.

Same category

More from Compliance

All entries →
9,237 inspections
242,618 defects found
30,388 defect types
Local franchise owners
Head office backing

Built to last. Inspected to be SURE.

One inspection, twelve months of advice, and the same person on the other end of the phone every time you call. That is the part you do not see on the brochure.

Same-day reports (subject to access and availability) 12 months free advice Your inspector reads every report
Start my quote
Or call 1300 787 327 business hours support

9,237 inspections · 242,618 defects found · Inspector-owned franchises