Skip to content
Defect type
High · 2–4/5

Stair Riser or Going Outside NCC Dimensional Limits

Compliance/stairs/standard/pre–1970, 1970–2000, 2000–2015/timber stair, concrete stair, metal stair

I measured riser heights and going depths across the flight and recorded dimensions outside the NCC 3.9.1 reference range, or I found more than 5mm variance between risers or goings in the same flight. In my experience non-standard dimensions cause trips and miscued steps, especially for elderly occupants and children. I see this frequently on owner-built renovations and in pre-1970 housing where the flight was cut to fit the available floor-to-floor height rather than set out to a published range.

Causes

  • Owner-builder cutting stair stringers to fit restricted floor-to-floor rise
  • Original construction predating current dimensional references
  • Landing added or removed altering the riser count and distribution
  • New floor covering (tile, overlay) added without adjusting the top or bottom riser
  • Deck or external stair built to a handyman rule-of-thumb rather than a referenced range

Symptoms to look for

  • I measured a riser at less than 115mm or greater than 190mm
  • I measured a going at less than 240mm or greater than 355mm
  • First or last riser varies from intermediate risers by more than 5mm on my tape
  • Occupants reporting trips, missed steps, or an awkward rhythm when descending
  • Visibly inconsistent riser heights along a single flight

Remedies

  • Rebuild the flight with consistent risers and goings; confirm against NCC 3.9.1
  • Shim or pack the top or bottom tread to equalise riser heights
  • Remove recent floor overlay contributing to the mismatched top riser
  • Engage a licensed carpenter to recut stringers to a referenced stair geometry
  • Fit high-visibility nosings as an interim measure while remediation is scheduled
Critical

Get an inspector through this property.

Findings in this category skew high severity. If you are under contract, we can usually book inside the cooling-off window. Every inspection includes 12 months of free advice.

Same category

More from Compliance

All entries →
9,237 inspections
242,618 defects found
30,388 defect types
Local franchise owners
Head office backing

Built to last. Inspected to be SURE.

One inspection, twelve months of advice, and the same person on the other end of the phone every time you call. That is the part you do not see on the brochure.

Same-day reports (subject to access and availability) 12 months free advice Your inspector reads every report
Start my quote
Or call 1300 787 327 business hours support

9,237 inspections · 242,618 defects found · Inspector-owned franchises