Water Leakage from Tap

Plumbing/real

Water Leakage from Tap is a high-severity plumbing defect SURE inspectors have documented across 36 inspection reports.

Causes

  • Water leakage from outside tap
  • Leaking toilet or wall tap
  • Worn tap components
  • Loose fitting
  • Leaking tap

Symptoms to look for

  • Water leakage detected from the outside tap
  • Visible water leakage from external tap
  • Water leakage from toilet/wall tap
  • Visible water leakage
  • Water leakage detected from the outdoor tap

Remedies

  • Engage a qualified plumber or other building expert to determine the full extent and estimated cost of repairs
  • Have a qualified plumber or other building expert determine the full extent and estimated cost of repairs
  • Consult a qualified plumber for a scope of works and cost of repairs
  • Liaise with a plumber to rectify
  • Consult a qualified plumber for a scope of works and cost of repairs.
Critical

Get an inspector through this property.

Findings in this category skew high severity. If you are under contract, we can usually book inside the cooling-off window. Every inspection includes 12 months of free advice.

Inspector-written

Curated entries in Plumbing

All entries →
  • Curated 2–4/5
    Air Conditioner Overflow Not Diverted

    The condensate overflow pipe from the air conditioning unit is discharging at or near the building perimeter rather than into a drain or away from the structure. Persistent moisture against the slab or wall base creates conducive conditions for termite ingress and can accelerate mortar deterioration over time.

  • Curated 2–4/5
    Hot Water Overflow Not Sufficiently Drained

    The TPR (temperature pressure relief) or overflow pipe from the hot water system discharges near the building perimeter rather than into a dedicated drain, directing water against the slab edge and creating sustained moisture - a recognised conducive condition for subterranean termites. AS/NZS 3500.4 requires relief valve discharge to be piped to a safe, visible location away from the structure.

  • Curated 2–4/5
    Galvanic Corrosion from Mixed Metal Pipework

    I traced the potable water pipework and found dissimilar metals joined directly - most often copper connected to older galvanised steel with no dielectric break. Reference: AS/NZS 3500.1. In my experience the galvanic cell at the junction accelerates corrosion, narrowing the bore, discolouring the water, and eventually causing pinhole leaks. I see this most on partial re-pipes over an older galvanised system.

  • Curated 3–5/5
    Polybutylene Pipework in Potable Water System

    I identified grey polybutylene pipework in the dwelling, installed during the late 1970s to mid-1990s window. The product was the subject of successive Plumbing Code advisories following widespread failures at acetal junction fittings. In my experience the risk of sudden splits and connection blow-outs rises sharply past 20 years of service, and I know insurers routinely flag or exclude cover on homes still running the system.

  • Curated 3–5/5
    Stormwater Cross-Connected to Sewer Drain

    I investigated a sewage odour reported after rain and traced a downpipe, surface drain, or sub-soil line into the sanitary sewer - an illegal cross-connection. Reference: AS/NZS 3500.3. In heavy rain the extra hydraulic load surcharges the sewer main, and in my experience sewage can back up into the house through floor wastes and gully traps. Owners also face penalties from the water authority.

  • Curated 3–5/5
    Hot Water System TPR Discharge Pipe Non-Compliant

    I followed the temperature and pressure relief valve discharge line from the storage hot water unit and it does not match the reference requirements I work from in AS/NZS 3500.4. I commonly record over-long runs, no visible air gap at the termination, upward runs that trap water, or the line terminating inside a cupboard or roof space. A failed discharge path stops the valve venting safely if it sticks - a scald and pressure hazard in my view.

Same category

More from Plumbing

All entries →
9,237 inspections
242,618 defects found
30,388 defect types
Local franchise owners
Head office backing

Built to last. Inspected to be SURE.

One inspection, twelve months of advice, and the same person on the other end of the phone every time you call. That is the part you do not see on the brochure.

Same-day reports (subject to access and availability) 12 months free advice Your inspector reads every report
Start my quote
Or call 1300 787 327 business hours support

9,237 inspections · 242,618 defects found · Inspector-owned franchises