Bedroom 2 Wall Deterioration And Cosmetic Cracks
Bedroom 2 Wall Deterioration And Cosmetic Cracks is a moderate-severity structural defect SURE inspectors have documented across 8 inspection reports.
Causes
- Wires chased into the wall (for light switch crack)
- General ageing and/or denting
- Wires chased into the wall
- Lack of maintenance
- Deteriorated paint
Symptoms to look for
- General ageing and/or denting and/or wear and/or previous wall patching on wall linings
- Cosmetic crack noted to wall above light switch
- Ageing and/or denting on wall linings
- Cosmetic crack above light switch
- Cosmetic crack noted to plaster
Remedies
- Engage a painter to repair deteriorated paint and patch/paint the cosmetic crack.
- A qualified painter should be engaged to assess and repair as required
- Engage a qualified painter to assess and repair as required
- Engage a painter to patch and paint cosmetic crack
- Engage a painter to repair deteriorated paint
Worth asking our inspector about this specifically.
This is common across Perth stock and usually fixable without drama, but the scope of the fix varies. Every SURE inspection includes 12 months of free advice. Call out the defect by name and we check for it directly.
Curated entries in Structural
- Curated 1–5/5External Wall Cracking Due to Settlement
Cracks in external masonry walls caused by ground movement or differential settlement of the footing system. Most observations are Category 0–2 under the BCA/AS 2870 scale (hairline to 5mm width) and represent cosmetic or minor structural concern, but a small proportion progress to Category 3–5 where structural engineer involvement is required. The crack pattern, location, and change over time determine whether this is a maintenance item or a structural event.
- Curated 1–4/5Obstructed Roof Void due to Insulation
Insulation, HVAC ducting, sarking, or stored items in the roof void prevent a complete inspection of ceiling joists and surrounding timbers. Our inspectors record this limitation because the obstructed zone could harbour undetected timber pest activity, moisture damage, or structural defects - none of which can be reported without visual access.
- Curated 1–5/5Restricted Roof Void Access due to Insulation
Insulation, sarking, HVAC ducting, or low clearance in the roof void prevents a complete visual inspection of ceiling joists, top plates, and perimeter timbers. When these areas are inaccessible, our inspectors cannot confirm whether timber pest activity, moisture damage, or structural defects are present - the limitation itself is a finding that the buyer needs to understand.
- Curated 1–5/5Timber Fungal Decay (Rot) in Fascia and Barge Boards
Fungal decay (wet rot or dry rot) in fascia and barge boards develops when timber is repeatedly wetted and unable to dry out - typically where paint has failed, where roof drainage is defective, or where the boards are end-grain exposed. Left unchecked it spreads into adjacent framing and rafter tails, converting a cosmetic repair into structural work.
- Curated 1–5/5Patched Wall Cracks
Previously cracked walls that have been patched or filled indicate prior ground movement or settlement. While the cosmetic repair may look sound at the time of inspection, the underlying cause - reactive soil movement, differential settlement, or footing inadequacy - may not have been addressed. Patched cracks that re-open signal ongoing movement and warrant structural assessment under AS 2870.
- Curated 1–5/5Leaning Fence Sections
Fence sections leaning out of plumb indicate post footing failure, material deterioration, or soil movement. A significantly leaning fence poses a safety risk - particularly for children - and will continue to worsen without intervention.