Non-compliant Balcony Step Down and Drainage System

Drainage/real

Non-compliant Balcony Step Down and Drainage System is a cosmetic drainage defect SURE inspectors have documented across 1 inspection report.

Causes

  • Construction not adhering to Australian Standards for balcony design and drainage
  • Inadequate implementation of alternative drainage solution

Symptoms to look for

  • Incorrect linear drain placement along door line
  • Insufficient 1:100mm fall away from dwelling
  • Missing water stop angles under door frame
  • Absence of minimum 75mm step-down

Remedies

  • Implement a compliant alternative solution with linear drain directly along the door line, water stop angles under the door frame, and a 1:100mm fall away from the dwelling
  • Reconstruct balconies to include a minimum 75mm step-down
Watch

Include this check in your next inspection.

Typically a low-severity finding, but worth documenting before maintenance work. Every SURE inspection includes 12 months of free advice.

Inspector-written

Curated entries in Drainage

All entries →
  • Curated 1–4/5
    Undrained Air Conditioner Overflow

    Split-system and ducted air conditioners produce condensate that must be piped away from the building. Where the overflow line terminates against the wall or discharges onto soil at the perimeter, repeated wetting creates conducive conditions for subfloor moisture, termite activity, and rising damp in adjacent masonry or framing.

  • Curated 1–4/5
    Inadequate Surface Water Drainage

    Where surface water cannot drain freely away from the building perimeter, it accumulates against footings and walls, creating persistent soil moisture that is a primary conducive condition for termite activity and footing movement. The BCA requires finished ground levels to fall away from the building at a minimum 1:100 grade for at least 1 metre at every external wall.

  • Curated 1–4/5
    Downpipes Not Connected to Storm Water

    One or more downpipes discharge directly onto the ground at the building perimeter rather than into a stormwater system. Water concentrates against footings, raising the risk of footing movement, rising damp, and termite conducive conditions - we find this in 22.1% of all Perth inspection reports.

  • Curated 1–3/5
    Debris in Gutters

    Leaf litter, dirt, and organic matter accumulating in gutters blocks downpipes and causes water to back up, overflow, and saturate fascia and eave linings. We see this in 17.5% of all Perth inspection reports - one of the most frequent maintenance defects on the books.

  • Curated 1–3/5
    Uneven Pathways

    Differential settlement of concrete or paved pathways creates raised or sunken sections that direct surface water toward the building rather than away from it. Our inspectors record this in 7.86% of all Perth reports. Beyond water ponding and potential moisture ingress at the perimeter, uneven surfaces present a trip-hazard that may engage liability considerations for vendors and landlords.

  • Curated 2–4/5
    Stormwater Drainage Directed Towards Building

    Site grading or paving directing stormwater runoff towards the building foundation rather than away from it. Causes subfloor moisture accumulation, rising damp, and potential foundation movement on reactive soils.

Same category

More from Drainage

All entries →
9,237 inspections
242,618 defects found
30,388 defect types
Local franchise owners
Head office backing

Built to last. Inspected to be SURE.

One inspection, twelve months of advice, and the same person on the other end of the phone every time you call. That is the part you do not see on the brochure.

Same-day reports (subject to access and availability) 12 months free advice Your inspector reads every report
Start my quote
Or call 1300 787 327 business hours support

9,237 inspections · 242,618 defects found · Inspector-owned franchises