Defect type ·201 observations
High · 2–4/5

Blocked Weep Holes

Drainage/real

Blocked Weep Holes is a high-severity drainage defect SURE inspectors have documented across 197 inspection reports. Highest concentration in Ellenbrook.

Causes

  • Improper installation of pavers/decking too close to the wall
  • Improper installation or placement of covers over weep holes
  • Design flaw or incorrect installation during construction
  • Soil, lawn, concrete paths or pavers covering weep holes
  • Pavers and concrete installed too close to the building

Symptoms to look for

  • Weep holes not effectively draining or positioned in an unsuitable location
  • Weep holes partially covered/blocked by filler, pavers, and soil
  • Potential for moisture build-up within wall cavities
  • Vents and weep holes visibly covered or obstructed
  • Weep holes obstructed by pavers / deck / turf

Remedies

  • Remove vegetation and/or lower soil levels so that sub floor vents are unobstructed and allowing free flowing air
  • Engage a landscaper to lower finished ground levels to fully expose all weep holes on the lower brick courses
  • Lower finished ground levels to fully expose all weep holes on the lower brick courses around the dwelling.
  • Clear weep holes and adjust landscaping/paths as necessary to ensure proper drainage and ventilation
  • Lower finished ground levels to fully expose all weep holes (remove filler/pavers if obstructing)
Inspection geography

Where we see this most

These suburbs show the highest concentration of blocked weep holes in our inspection data (minimum five observations). Click a suburb to see its full defect profile.

Critical

Get an inspector through this property.

Findings in this category skew high severity. If you are under contract, we can usually book inside the cooling-off window. Every inspection includes 12 months of free advice.

Inspector-written

Curated entries in Drainage

All entries →
  • Curated 1–4/5
    Undrained Air Conditioner Overflow

    Split-system and ducted air conditioners produce condensate that must be piped away from the building. Where the overflow line terminates against the wall or discharges onto soil at the perimeter, repeated wetting creates conducive conditions for subfloor moisture, termite activity, and rising damp in adjacent masonry or framing.

  • Curated 1–4/5
    Inadequate Surface Water Drainage

    Where surface water cannot drain freely away from the building perimeter, it accumulates against footings and walls, creating persistent soil moisture that is a primary conducive condition for termite activity and footing movement. The BCA requires finished ground levels to fall away from the building at a minimum 1:100 grade for at least 1 metre at every external wall.

  • Curated 1–4/5
    Downpipes Not Connected to Storm Water

    One or more downpipes discharge directly onto the ground at the building perimeter rather than into a stormwater system. Water concentrates against footings, raising the risk of footing movement, rising damp, and termite conducive conditions - we find this in 22.1% of all Perth inspection reports.

  • Curated 1–3/5
    Debris in Gutters

    Leaf litter, dirt, and organic matter accumulating in gutters blocks downpipes and causes water to back up, overflow, and saturate fascia and eave linings. We see this in 17.5% of all Perth inspection reports - one of the most frequent maintenance defects on the books.

  • Curated 1–3/5
    Uneven Pathways

    Differential settlement of concrete or paved pathways creates raised or sunken sections that direct surface water toward the building rather than away from it. Our inspectors record this in 7.86% of all Perth reports. Beyond water ponding and potential moisture ingress at the perimeter, uneven surfaces present a trip-hazard that may engage liability considerations for vendors and landlords.

  • Curated 2–4/5
    Stormwater Drainage Directed Towards Building

    Site grading or paving directing stormwater runoff towards the building foundation rather than away from it. Causes subfloor moisture accumulation, rising damp, and potential foundation movement on reactive soils.

Same category

More from Drainage

All entries →
9,237 inspections
242,618 defects found
30,388 defect types
Local franchise owners
Head office backing

Built to last. Inspected to be SURE.

One inspection, twelve months of advice, and the same person on the other end of the phone every time you call. That is the part you do not see on the brochure.

Same-day reports (subject to access and availability) 12 months free advice Your inspector reads every report
Start my quote
Or call 1300 787 327 business hours support

9,237 inspections · 242,618 defects found · Inspector-owned franchises