Poor Workmanship of Internal Wall Finish
Poor Workmanship of Internal Wall Finish is a moderate-severity finishes defect SURE inspectors have documented across 5 inspection reports.
Causes
- Poor workmanship during previous rectification works involving plasterboard sheeting installation and finishing.
- Poor workmanship by the contractor during eaves replacement
- Substandard plastering work
- Poor workmanship during Gyprock installation and finishing
Symptoms to look for
- Raised and uneven surface areas at fixing points due to inadequate sanding
- Uneven and poorly finished sections on the eaves
- No consistent or uniform finish achieved
- Visibly apparent plasterboard joints
- Rough and uneven joint areas
Remedies
- Achieve a smooth, uniform wall surface consistent with accepted industry standards (Level 4 under AS/NZS 2589) prior to repainting
- Proper re-flushing, sanding, and finishing of all joints and fixing points
- Engage a qualified contractor to rectify the poor finish of the eaves
- Rectification by a qualified and competent plasterer
- Rectify the Gyprock set finish to meet Level 4 standards
Worth asking our inspector about this specifically.
This is common across Perth stock and usually fixable without drama, but the scope of the fix varies. Every SURE inspection includes 12 months of free advice. Call out the defect by name and we check for it directly.
Curated entries in Finishes
- Curated 1–3/5Common Cracks and Settlement in Pathways
Cracking and uneven settlement in concrete footpaths, driveways, and porch slabs is one of the most frequently observed external defects in Perth homes, present in 11.66% of all reports. Most findings are minor and reflect the expected behaviour of unreinforced concrete slabs on reactive soils, though tree-root intrusion and poor drainage can accelerate movement to a point where trip hazards develop.
- Curated 1–4/5Surface Rust on Pergola Frame
Surface oxidation on steel pergola frames is one of the more frequent cosmetic findings in Perth pre-purchase reports, appearing in 11.19% of all inspections. Left untreated, surface rust progresses through the coating into the base metal, eventually compromising the structural integrity of posts and beams. Early intervention with surface treatment is straightforward; through-corrosion is not.
- Curated 2–4/5Cracked Floor Tiles in Wet Areas
Cracked, loose, or drummy floor tiles in bathrooms, laundries, and kitchens. Allows moisture penetration to the substrate, potentially compromising waterproof membrane integrity and causing concealed water damage.
- Curated 1–3/5Damaged Eave Lining
Damage to the underside lining of the eaves - including cracking, holes, gaps at junctions, and poorly cut penetrations around downpipes - is recorded in 8.78% of all inspection reports. Beyond the cosmetic concern, openings in eave lining allow birds, possums, and insects to access the roof cavity and can accelerate timber deterioration where moisture also enters.
- Curated 1–3/5Eave Deterioration and Ageing
General weathering and paint breakdown on eave linings, timber rafter ends, and quad trim is one of the most common findings on Perth homes built before 2000. Left unattended, deteriorated eaves allow moisture into the roof perimeter, accelerating rot in rafter ends and creating conducive conditions for timber pests.
- Curated 1–3/5Defective Door Handles, Hinges, and Locks
Malfunctioning or worn door hardware including loose handles, squeaking hinges, misaligned latches, and non-functioning locks. High-frequency defect across all building eras, typically cosmetic but can affect security and fire egress.