Skip to content
Perth Cockburn Corridor 1,521 people

Building Inspections in Cockburn Central, Perth

30 Defects indexed
260 In sample
1,521 Population

Stock profile · ABS 2021 Census

What’s here in Cockburn Central

Separate houses
26.8%
Semi-detached / townhouse
1.2%
Flats & apartments
73.0%

745 occupied private dwellings

Local profile · ABS 2021 Census

Who lives in Cockburn Central

Median age
31yrs
0
Industry reports covering this area
30
Defects indexed in Cockburn Central postcode
Postcode area
260
Inspections sampled in DefectIndex

Top defects in Cockburn Central

Five issues we find most.

From 260 SURE inspections in Cockburn Central. Each defect is anonymous. No property is identified.

30 defect types indexed across 260 inspections

  1. 01
    45.8%
    of inspections
    Mulch and Garden Beds Against House
    Termite Moderate 119 cases Curated entry
  2. 02
    29.6%
    of inspections
    High Termite Risk Due to Environmental Surrounds
    Termite Moderate 78 cases Curated entry
  3. 03
    39.2%
    of inspections
  4. 04
    61.2%
    of inspections
    External Wall Cracking Due to Settlement
    Structural Moderate 231 cases Curated entry
  5. 05
    34.2%
    of inspections
    Undrained Air Conditioner Overflow
    Drainage Moderate 89 cases Curated entry
  6. 06
    28.5%
    of inspections
    External Door Paint Deterioration
    Finishes Cosmetic 79 cases
  7. 07
    15.4%
    of inspections
  8. 08
    26.2%
    of inspections
    Excessive Moisture Readings
    Moisture Major 68 cases Curated entry
  9. 09
    21.9%
    of inspections
    Concealed Internal Wall Areas (Termite Risk)
    Termite Moderate 57 cases Curated entry
  10. 10
    36.9%
    of inspections
    Bedroom 2 Ceiling/Cornice Join Crack
    Finishes Cosmetic 96 cases
  11. 11
    37.7%
    of inspections
    Trees in Close Proximity to Dwelling
    Soil & Foundation Moderate 98 cases Curated entry
  12. 12
    22.3%
    of inspections
    Restricted Roof Void Access due to Insulation
    Structural Moderate 65 cases Curated entry
  13. 13
    19.2%
    of inspections
    Mulch and Garden Beds Close to House
    Drainage Moderate 50 cases
  14. 14
    16.2%
    of inspections
    Stains on Garage Floor
    Finishes Cosmetic 42 cases
  15. 15
    18.5%
    of inspections
    Air Conditioner Overflow Not Diverted
    Plumbing Moderate 48 cases Curated entry
  16. 16
    19.2%
    of inspections
  17. 17
    17.3%
    of inspections
    Outdated Termite Treatment Barrier
    Termite Major 45 cases Curated entry
  18. 18
    13.8%
    of inspections
    Patched Wall Cracks
    Structural Moderate 45 cases Curated entry
  19. 19
    18.8%
    of inspections
    Cracked Roof Mortar
    Roofing Moderate 74 cases Curated entry
  20. 20
    15.0%
    of inspections
    Deteriorated Splashback Sealant
    Moisture Minor 47 cases Curated entry
  21. 21
    17.7%
    of inspections
    Obstructed Roof Void due to Insulation
    Structural Moderate 58 cases Curated entry
  22. 22
    17.3%
    of inspections
    Inadequate Surface Water Drainage
    Drainage Moderate 48 cases Curated entry
  23. 23
    16.5%
    of inspections
    Eave Lining Stains
    Roofing Minor 43 cases Curated entry
  24. 24
    15.4%
    of inspections
    Excess Moisture in Walls Adjacent to Wet Areas
    Moisture Moderate 44 cases Curated entry
  25. 25
    15.4%
    of inspections
    Nail Popping in Hallway Ceiling
    Finishes Minor 43 cases
  26. 26
    16.2%
    of inspections
    Inadequate Slab Edge Exposure
    Soil & Foundation Moderate 42 cases
  27. 27
    15.8%
    of inspections
    Debris in Gutters
    Drainage Minor 42 cases Curated entry
  28. 28
    17.7%
    of inspections
    Tree Stumps on Site
    Termite Moderate 46 cases Curated entry
  29. 29
    15.4%
    of inspections
    Downpipes Not Connected to Storm Water
    Drainage Moderate 40 cases Curated entry
  30. 30
    17.7%
    of inspections
    Timber in Contact with Ground
    Termite Major 54 cases Curated entry

Common issues in Cockburn Central

Lack of Subterranean Termite Management Program External Wall Cracking due to Settlement Concealed Slab Edge

DefectIndex

SURE has indexed 30 defects across 260 inspections in the Perth region. That data underlies every finding we report in Cockburn Central.

Location

Cockburn Central and surrounding suburbs

Loading location map

Map data © OpenStreetMap contributors · Tiles © CARTO

FAQs — Cockburn Central inspections

Questions we hear about Cockburn Central

Are termites a common issue in Cockburn Central?

In Cockburn Central, our reports have identified a Lack of Subterranean Termite Management Program in 28.6% of inspections. This highlights the importance of checking for current termite management systems and potential timber pest activity. Our inspectors are trained to identify signs of past or present termite activity and conditions conducive to infestations.

Who will be inspecting my property in Cockburn Central?

Your inspection in Cockburn Central will typically be conducted by Kim Steele. Kim is a certified inspector covering the Perth northern and north-eastern corridor, holding certifications CPPHON4013 and CPPUPM3008. Kim's expertise ensures a thorough and professional assessment of your potential property.

What is the turnaround time for an inspection report and what support is offered afterwards?

We aim to deliver your comprehensive inspection report within 24 hours of the inspection where access and availability allow. After you receive your report, Kim Steele is available for 12 months of free phone consultation. This allows you to discuss any findings or concerns as you move forward with your property purchase.

What are the most common building defects found in Cockburn Central?

Based on an indicative sample of 260 SURE inspections carried out in Cockburn Central postcode area (6164), the most common defects we identify are: External Wall Cracking due to Settlement, Mulch and Garden Beds Against House, Slab Edge Concealed by Soil, Paving, or Raised Garden Beds, Trees in Close Proximity to Dwelling, Bedroom 2 Ceiling/Cornice Join Crack.

Are termite or timber pest concerns common in Cockburn Central?

Yes. Across 260 inspections in Cockburn Central postcode area (6164), the most common timber-pest findings include Mulch and Garden Beds Against House, Slab Edge Concealed by Soil, Paving, or Raised Garden Beds, High Termite Risk Due to Environmental Surrounds. We recommend a timber-pest inspection alongside any pre-purchase building inspection here.

What structural issues are typical for homes in Cockburn Central?

Common structural findings we record in Cockburn Central postcode area (6164) include External Wall Cracking due to Settlement, Obstructed Roof Void due to Insulation, Patched Wall Cracks. Each finding is reported alongside remedy recommendations and covered by 12 months free advice.

Is moisture a concern in Cockburn Central homes?

Excessive Moisture Readings and Deteriorated Splashback Sealant are among the moisture-related findings recorded across 260 inspections in Cockburn Central postcode area (6164). Our inspectors use moisture-meter readings to quantify any issue they detect.

Built to last. Inspected to be SURE.

One inspection, twelve months of advice, and the same person on the other end of the phone every time you call. That is the part you do not see on the brochure.

Same-day reports (subject to access and availability) 12 months free advice Your inspector reads every report
Start my quote
Or call 1300 787 327 business hours support

9,237 inspections · 242,618 defects found · Inspector-owned franchises

Your free area report

Get your free area report in 30 seconds

A suburb-specific PDF with defect profiles from real SURE inspections in Cockburn Central, price trends, school data, and era-aware inspection guidance, emailed within two minutes. Just 4 fields.

  • Defect profile: top issues found in real SURE inspections in Cockburn Central.
  • Price trends & school data: local context to inform your decision.
  • No paywall. No commitment. Just 4 fields, 30 seconds.

Your report is emailed within 2 minutes. Signed download link expires in 24 hours.