Defect type ·108 observations
High · 2–4/5

Unverified Electrical System

Electrical/real

Unverified Electrical System is a high-severity electrical defect SURE inspectors have documented across 108 inspection reports. Highest concentration in Alkimos.

Causes

  • Limitations of the general building inspection scope (does not cover electrical systems)
  • Standard inspection limitation (inspector does not certify electrical systems)
  • Scope limitation of building inspection report
  • Scope limitation of current inspection
  • Scope limitation of the inspection

Symptoms to look for

  • Unknown safety or functional condition of electrical wiring and components
  • No certification for electrical wiring or safety was performed
  • Unknown safety or compliance status of the electrical system
  • Electrical system functionality and safety not assessed
  • Lack of certified electrical assessment

Remedies

  • Ensure RCDs (Residual Current Devices) and smoke alarms are certified by a qualified electrician BEFORE settlement
  • Engage a licensed electrician to assess all electrical wiring and components for safety and compliance
  • Have all electrical wiring and components assessed by a licensed electrician
  • Have an electrical report carried out by a suitably qualified contractor
  • Have all electrical wiring and components assessed by a licensed electrician.
Inspection geography

Where we see this most

These suburbs show the highest concentration of unverified electrical system in our inspection data (minimum five observations). Click a suburb to see its full defect profile.

Suburb
Reports
Share
Avg sev
Alkimos
7
0.1%
3.43
Ellenbrook
7
0.1%
3.71
Critical

Get an inspector through this property.

Findings in this category skew high severity. If you are under contract, we can usually book inside the cooling-off window. Every inspection includes 12 months of free advice.

Inspector-written

Curated entries in Electrical

All entries →
  • Curated 3–5/5
    Exposed Electrical Wiring in Accessible Area

    Electrical wiring not properly enclosed in conduit or behind wall linings in areas accessible to occupants, including subfloor spaces, garages, and laundries. Presents shock hazard and does not comply with AS/NZS 3000 wiring rules.

  • Curated 2–5/5
    Non-Compliant or Overloaded Switchboard

    Switchboard not meeting current AS/NZS 3000 requirements, including missing RCDs (safety switches), overcrowded circuits, or outdated ceramic fuses. Common in pre-2000 Perth and Sydney homes that have not been upgraded.

Same category

More from Electrical

All entries →
9,237 inspections
242,618 defects found
30,388 defect types
Local franchise owners
Head office backing

Built to last. Inspected to be SURE.

One inspection, twelve months of advice, and the same person on the other end of the phone every time you call. That is the part you do not see on the brochure.

Same-day reports (subject to access and availability) 12 months free advice Your inspector reads every report
Start my quote
Or call 1300 787 327 business hours support

9,237 inspections · 242,618 defects found · Inspector-owned franchises